805U-E Wireless Ethernet User Manual
Man_805U-E Rev 1.5 Page 54
Client 1 Configuration
Perform the same configuration steps as the Access Point configuration with the following
differences:
set IP address of 805U-E to 192.168.0.201
set the Operating Mode to Client.
Ensure the same System Generator String is used and the same Radio Encryption method is
selected.
Client 2 Configuration
As above, but use IP address 192.168.0.202
Alternate procedure – Adjust 805U-E network settings using serial
port(assuming configuration PC is on existing network)
a) Open terminal program with settings with data rate 19200bps, 8 data bits,
1 stop bit and no parity.
b) Set dipswitch to SETUP
c) Connect straight through serial cable to 805U-E and power up unit.
d) When prompted, strike the Enter key to abort automatic boot
e) Set IP address of 805U-E to 192.168.0.200 with command bip
192.168.0.200
f) Set netmask of 805U-E to 192.168.0.200 with command bnm
255.255.255.0
g) Set gateway address of 805U-E to 192.168.0.1 with command /jointfilesconvert/286502/bgw
192.168.0.1
h) Set dipswitch to RUN
i) Reset 805U-E with reset command.
j) Open configuration webpage with Internet Explorer at address
http://192.168.0.200/
When prompted for password, enter default username “user” and password
“user”
Enter “Quick Start”, and select Access Point.
IP address should be 192.168.0.200
Enter a System Generator String
Select the Radio Encryption required.
Save the changes.